A hanging protocol (HP) is a set of stored image layouts that can be automatically applied as studies are loaded.  Without them, you need to organize the images on the screen to your liking each time you load a study.  

Hanging Protocol Tool Image Added

The Hanging Protocol tool is used to show the HP manager as well as provide quick access to applicable HPs for the current study.  If this tool is not present in the toolbar you can add it via Tools → Customize → Show Hanging Protocol Manager and clicking on the corresponding "Toolbar" checkbox.  Alternatively, you can show the HP manager via the menu at Tools → Standard → Show Hanging Protocol Manager.

Default Layouts

OnePacs Workstation comes bundled with predefined Hanging Protocols that are applied automatically.  Until you create some HPsyour own hanging protocols, the workstation will layout images according to the default protocols or layouts as specified per modality in the Layout Options screen (Tools –> Options –> Layout) which defaults to 1×2 for all modalities.  In this mode, the primary study (the one selected by the user for loading) will be shown in the upper-left image box, and the most recent priors will flow from left –> right, top –> bottom.  .  The default HP for most exams is a 1×2 layout with the current exam on the left and most recent prior on the right.  If no priors are present, both tiles will be filled with series from the current exam.  MG studies have unique default protocols tailored for Mammography

Creating a Hanging Protocol

To create a hanging protocol, activate the Hanging Protocol Tool Image Removed.  This will show the Hanging Protocol Manager as described above.  Initially, a default HP is automatically created based on your current layout settings and loaded studies, but it is not shown in the list.  If you were to simply click the Add button , make layout changes and click the Save button , then any time you loaded a similar study, it would be displayed the same way.  By default, a new HP is set up with only one matching rule: that the loading study should match the specified modality.  As a simple example, if you create a HP from a CT study, then it will apply to every future loaded CT study and lay them out the same way.  

...

When a HP is being applied to a study, its layout is first applied to divide the screen space into image boxes and tiles.  At that point, the image boxes have to be filled with series; but which ones?  The ones you wanted to see, of course!  But how would it know that?  This is where the Study and Series Selection Criteria come into play.  They are rule sets that behave just like the Matching Criteria.  For each image box, first, the Study Selection Criteria are evaluated to pick the study that is the best match (i.e. the one with the highest score).  Then the Series Selection Criteria are evaluated for all series in that study to pick the best matching series; that's the one that gets displayed.  

There are a few twists.  There is one special “DICOM tag” (StudyType), and two special Comparitors (SameAsPrimary and SameAsImageBox) used to make these rules smarter.  Let's consider the scenarios where they are needed.  

In most cases, when multiple studies are displayed simultaneously, the user's main goal is to compare the “primary” study (the one selected when launching the workstation) with other similar recent studies for the same patient.  In that case, the obvious choice would be to show series of the same modality and body part.  These special rule features make it possible to do that.  

Here's how they work.  When a rule's DICOM tag is “StudyType” (which isn't a DICOM tag at all, but it's used like one here), the only value that makes sense is “Primary”.  When a rule is set up like that, it will pass if it's evaluated against the primary study, and fail otherwise.  This is done to anchor the primary study in the image box of your choice.  If you like to read left to right, you'd place the primary study in the left-most image box and set FlowDirection to LeftToRight.  Doing so automatically creates a Study Selection rule for that image box with:

  • DicomTag Property = [StudyType]
  • Comparitor = Equals
  • Value = Primary 

You don't have to set these values - it's done automatically when you place the primary study in an image box.  Also, when you alter the layout (change it from 1×2 to 2×2 for example), the other image boxes are instantly filled with similar recent studies from the same patient, and series of the same modality and body part (if available), and those choices are recorded in the HP as follows:

  • DicomTag Property = [Modality]
  • Comparitor = SameAsPrimary
  • Value = Blank 

Note that the value is blank because it's not comparing to the DICOM tag in the series, it's comparing it to the DICOM tag in the primary study's selected series!  Again, you don't have to set up these rules by hand, it's done for you.  Of course, you can alter them if you like, but in most cases, you won't need to.

Another common scenario involves displaying multiple series from one study at the same time in different image boxes.  It could be that your studies contain different views of the same body part that you like to see simultaneously.  The SameAsImageBox comparitor is used to do that.  This happens when you select a series in one image box from the same study that's already being displayed in another image box.  That's all you need to do; again, the rule is set up for you.

When an HP is set up using these special rule features, and saved, then similar studies you load in the future should be organized on the screen the same way every time.

...