Date: Thu, 28 Mar 2024 15:42:16 -0400 (EDT) Message-ID: <1828145310.1636.1711654936784@[10.0.0.37]> Subject: Exported From Confluence MIME-Version: 1.0 Content-Type: multipart/related; boundary="----=_Part_1635_1146266839.1711654936781" ------=_Part_1635_1146266839.1711654936781 Content-Type: text/html; charset=UTF-8 Content-Transfer-Encoding: quoted-printable Content-Location: file:///C:/exported.html
Yes. All studies which are transmitted to OnePacs are also stored locall= y at your facility on the computer which is used to send studies to OnePacs= . In the event of loss of internet access by your facility, you may retriev= e and review studies directly from your facility's Gateway PC (OnePacs tran= smission computer). The Gateway in fact may be configured as a robust, long= -term DICOM archive and may serve as your main repository of imaging inform= ation. If you choose to archive your studies locally on the transmission co= mputer, this service is entirely free and requires no payments to OnePacs. = Such users can continue to use the free version of OnePacs for the web-enab= led worklist, report and image distribution, and other features. Please see= this link for fur= ther details.
This may be due to security measures at your local facility blocking acc= ess to the OnePacs site. You may need to have your IT staff add an exceptio= n for the following URL:
The OnePacs Workstation for Windows, version 9.5 or higher, or for macOS= , version 2 or higher, may be used for interpreting digital mammography in = the US. Lossy compressed mammographic images and digitized film screen imag= es must not be reviewed for primary diagnosis or image interpretation. For = primary diagnosis, post process DICOM "for presentation" images must be use= d. Mammographic images should only be viewed with a monitor approved by FDA= for viewing mammographic images.
In addition to the OnePacs Workstation, mammographic images may be revie= wed using sofrware from third party vendors, such as:
for Windows:
For macOS:
Yes, the OnePacs Workstation provides user-specific hanging protocols.
No. The OnePacs Workstation is a 64-bit application. = p>
Yes, by default the Gateway will allow called AE titles of ONEPACS, GATE= WAY, and the AE title assigned to you in the welcome email. To support addi= tional AE titles please perform the following steps.
Yes, to change the DICOM port of the gateway execute the following steps= :
Yes, please refer to these instructions.
The Gateway compresses and sends the images over a TLS encrypted connect= ion. When sending from an imaging modality or PACS system, to assure that t= he images are sent rapidly and securely it is necessary to send via the Gat= eway.
It is also possible for users to upload studies directly to OnePacs thro= ugh manual interaction with the web-based worklist. Instructions for this a= re listed here
Yes, we would be happy to store some sample DICOM images to your account= for you to evaluate the OnePacs web application and workstation. Please se= nd an email to support@onepacs.com requesting this if you so desir= e.
If you would like a demo via Webinar please send a request to suppo= rt@onepacs.com.
There are a couple ways of doing this.
or